марки

    • HF-Essential II for TL5 and TL-D

      HF-E 136 TL-D II 220-240 50/60Hz
      HF-E 136 TL-D II 220-240 50/60Hz

      HF-E 136 TL-D II 220-240 50/60Hz

      Order code: 77056500

      Full Product Code: 871829177056500

    Specifications Show all

    General Information
    Lamp Type
    TL-D II
    Number of Lamps
    1/2 piece/unit
    Number of Products on MCB (16A Type B) (Nom)
    20
    Automatic Restart
    Yes
    Operating and Electrical
    Input Voltage
    220 to 240 V
    Input Frequency
    50 to 60 Hz
    Operating Frequency (Nom)
    49.4 kHz
    Crestfactor (Nom)
    1.8
    Power Factor 100% Load (Nom)
    0.97
    Preheat Time
    1.4 s
    Mains Voltage Performance (AC)
    220-240V
    Mains Voltage Safety (AC)
    184-276V
    Earth Leakage Current (Max)
    0.5 mA
    Inrush Current Width
    0.37 ms
    Ballast Factor (Nom)
    0.95
    Power Losses (Nom)
    3.74 W
    Inrush Current Peak (Max)
    15 A
    Wiring
    Connector Type Input Terminals
    Insert
    Cable Capacity Output Wires Mutual (Max)
    150 pF
    Connector Type Output Terminals
    Insert
    Cable Length Hot Wiring
    0.75 m
    Wire Striplength
    8.0-9.0 mm
    Dual Fixture Master/Slave
    Possible, lamp wires 0.75m max. length  [ Master/Slave operation possible]
    Input Terminal Cross Section
    0.50-1.50 mm²
    Output Terminal Cross Section
    0.50-1.50 mm²
    Cable Capacity Cold Output Wires - Earth (Max)
    150 pF
    Cable Capacity Hot Output Wires - Earth (Max)
    150 pF
    System characteristics
    Rated Ballast-Lamp Power
    36/18 W
    Lamp Power on TL-D
    29.84 W
    Power Loss on TL-D
    3.74 W
    Temperature
    T-Ambient (Max)
    50 °C
    T-Ambient (Min)
    -10 °C
    T-Storage (Max)
    50 °C
    T-Storage (Min)
    -20 °C
    T-Case Lifetime (Nom)
    80 °C
    T-Case Maximum (Max)
    80 °C
    Mechanical and Housing
    Housing
    L 150x40x28
    Emergency Operation
    Nominal Light Output After 60 Seconds
    100% of EBLF
    Normal Operating Voltage (DC)
    220-240 V
    Battery Voltage Guaranteed Operation
    176-275 V
    Battery Voltage Guaranteed Ignition
    186-275 V
    Emergency Ballast Lumen Factor (EBLF) (Nom)
    100 %
    Nominal Light Output After 5 Seconds
    50% of EBLF
    Approval and Application
    Energy Efficiency Index
    A2
    IP Classification
    IP 20  [ Ingress Protection 20]
    EMI 9 kHz ... 30 MHz
    EN55015
    Vibration Standard
    IEC60068-2-6_2007-Fc
    Bumps Standard
    IEC 60068-2-29 Eb
    Approval Marks
    CE marking
    CB Certificate
    KEMA Keur certificate
    RoHS Compliant
    Hum And Noise Level
    < 30 dB(A)
    Product Data
    Full product code
    871829177056500
    Order product name
    HF-E II 136 TL-D 220-240V 50/60Hz
    EAN/UPC - Product
    8718291770565
    Order code
    77056500
    Numerator - Quantity Per Pack
    1
    Numerator - Packs per outer box
    20
    Material Nr. (12NC)
    913713041066
    Net Weight (Piece)
    0.090 kg
    Installation Diagrams
    HF-E II 136 TL-D 220-240V 50/60Hz
    HF-E II 136 TL-D 220-240V 50/60Hz
    HF-E 136 TL-D II; Keep wires 1 &amp; 2 short
    HF-E 136 TL-D II; Keep wires 1 & 2 short