HF-Performer III for TL5 lamps

HF-P 2 14-35 TL5 HE III 220-240V

HF-P 2 14-35 TL5 HE III 220-240V

  • Unsurpassed energy-efficient and long-lasting solution

    Product information

    Downloads

    Leaflet
    Size:208.7 kB

    See all downloads

Videos

[trigger to render Video Gallery]

Images

Specifications Show all

General Information
Application Code
III
Type Version
IDC
Lamp Type
TL5 HE
Number Of Lamps
2 piece/unit
Number Of Products On MCB (16A Type B) (Nom)
28
Automatic Restart
Yes
Operating and Electrical
Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Operating Frequency (Nom)
46 kHz
Ignition Method
Programmed Start
Crestfactor (Max)
1.7
Power Factor 100% Load (Nom)
0.94
Ignition Time (Max)
1.2 s
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Earth Leakage Current (Nom)
0.5 mA
Inrush Current Width
0.25 ms
Constant Wattage Deviation
-2%/+2%
Ballast Factor (Nom)
0.925
Power Losses (Nom)
2.8-5.6 W
Inrush Current Peak (Max)
24 A
Wiring
Connector Type Input Terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Capacity Output Wires Mutual (Nom)
200 pF
Connector Type Output Terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Length Hot Wiring
0.75 m
Wire Striplength
8.0-9.0 mm
Dual Fixture Master/Slave
Not applicable  [ Master/Slave oper. not applicable]
Input Terminal Cross Section
0.50-1.00 mm²
Output Terminal Cross Section
0.50-1.00 mm²
Cable Capacity Output Wires To Earth (Nom)
200 pF
System characteristics
Rated Ballast-Lamp Power
14-35 W
Rated Lamp Power On TL5 HE
14/35 W
System Power On TL5 HE
36.8/75.6 W
Lamp Power On TL5 HE
28.0/70.0 W
Power Loss On TL5 HE
2.8/5.6 W
Temperature
T-Ambient (Max)
60 °C
T-Ambient (Min)
-25 °C
T-Storage (Max)
80 °C
T-Storage (Min)
-40 °C
T-Case Lifetime (Nom)
80 °C
T-Case Maximum (Max)
80 °C
T-Ignition (Max)
60 °C
T-Ignition (Min)
-25 °C
Mechanical and Housing
Housing
L360x30x22
Emergency Operation
Nominal Light Output After 60 Seconds
100% of EBLF
Battery Voltage Lamp Ignition
176-276 V
Normal Operating Voltage (DC)
220-240 V
Battery Voltage Lamp Operation
176-276
Battery Voltage Guaranteed Operation
176-275 V
Battery Voltage Guaranteed Ignition
186-275 V
Emergency Ballast Lumen Factor (EBLF) (Nom)
0.7 %
Nominal Light Output After 5 Seconds
50% of EBLF
Approval and Application
Energy Efficiency Index
A2 BAT
EMI 9 kHz ... 30 MHz
EN55015
EMI 30 MHz ... 1000 MHz
-
Safety Standard
IEC 61347-2-3
Performance Standard
IEC 60929
Quality Standard
ISO 9000:2000
Environmental Standard
ISO 14001
Harmonic Current Emission Standard
IEC 61000-3-2
EMC Immunity Standard
IEC 61547
Vibration Standard
IEC68-2-6 F c
Bumps Standard
IEC 68-2-29 Eb
Humidity Standard
EN 61347-2-3 clause 11
Approval Marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature Marking
Yes
Emergency Standard
IEC 60598-2-22
Hum And Noise Level
< 30 dB(A)
Product Data
Full product code
872790090503800
Order product name
HF-P 2 14-35 TL5 HE III 220-240V
EAN/UPC - Product
8711500999238
Order code
90503800
Numerator - Quantity Per Pack
1
Numerator - Packs per outer box
12
Material Nr. (12NC)
913713031166
Net Weight (Piece)
0.245 kg
Installation Diagrams
HF-P 2 TL-D/TL5 (keep wires 1;2 &amp; 5;6 short)
HF-P 2 TL-D/TL5 (keep wires 1;2 & 5;6 short)
Performance Diagrams

Recently Viewed

    • Управлявайте проектите си с MyProjects
      Използвайте MyProjects да създавате, запазвате, управлявате и споделяте елементи и проекти с колегите и членовете на екипа си.
You are now visiting our Global professional lighting website, visit your local website by going to the USA website